Earth Leakage Circuit Breaker




Our company is a well known Manufacturer and Supplier of Earth Leakage Circuit Breaker [ELCB] from Ahmedabad, Gujarat. These breakers are highly sensitive and can easily detect current leakage before it becomes a big risk. Customers can be assured of receiving a quality Earth Leakage Circuit Breaker  [ ELCB ] from us that conforms to BS standard 4293: 1983.

Highlights :

  • A high sensitive current operated Earth Leakage Circuit Breaker  [ ELCB ]
  • Specially designed to give protection by disconnecting the power supply against risk of dangerous & possible lethal electric shocks
  • Detects dangerous leakage current exceeding the generally accepted safe limit of 30mA & isolates the effected section of installation
  • Confirms to BS standard 4293: 1983
  • Highly sensitive and high speed response unit
  • Sensitivity-based on rated tripping level from 3mA to 30mA
  • Response speed-Within 30m sec. of leakage exceeding set limits


How It Operates?
ACTIVE High sensitive current operated  Earth Leakage Circuit Breaker  [ ELCB ] incorporates an active current transformer, to sense the sum of all current to be normally zero. Normally current flowing through phase passes through the neutral through load so resultant voltage in an active transformer is zero. In case of any leakage to earth, core balance transformer senses as unbalance & small signal voltage is generated in secondary winding which is fed to solid state electronic circuit of ELCB. This is amplified and immediately activates the tripping mechanism of the unit. Hence, resulting in switching off and isolating the defective installation. This highly sophisticated Earth Leakage Circuit Breaker system (ELCB), based on the latest & ultimate in electronics design; is specifically engineered to protect you from dangerous electric shock and your equipment from High Voltage, Low Voltage, Overload and Short circuit. There are LED indications provided on the front panel display which informs you that your ELCB has sensed Fault and display its Fault status with LED indication along with Emergency Light and Audible Emergency Signal - Siren. After fault recovery, control circuit having inbuilt time delay will be activated within 5 seconds instantly and ELCB will be ON automatically-Fully Automatic (self start).


Specifications

Automation Grade Automatic
Material Plastic
Rated Voltage 230V
Rated Current 6-100a
Warranty 1 Year
No. of Poles 2


光棍影院手机PROTECTIONS

MODE E/L = EARTH LEAKAGE O/L = OVERLOAD H/V = HIGH VOLT.
L /V =  LOW VOLT.
WORKING Available Available Available
BYPASS(1) × Available Available
BYPASS(2) × × ×

RATINGS

PARAMETERS
Particulars 1-phase 3-phase
Rated  Voltage 230±10% Volt A.C. 50Hz. 415±10% Volt A.C. 50Hz.
Rated  Load Current 0-32  Amp (Adjustable) 0-32  Amp (Adjustable)

光棍影院手机EXCLUSIVE HIGH PERFORMANCE FEATURES

Protection 1 Earth Leakage Current 3 - 30mAmp. (Adjustable) For Shock Protection
2 Overload   0 - 32 Amp Overload set. For equipment Safety
3 Short  circuit Inbuilt  Overload function For  total premises Safety
4 High Voltage Cut-off / Cut-in Above  305 Volt. A.C./ Below  290 Volt. A.C. For equipment Safety
5 Low Voltage Cut-Off / Cut-in Below  160 Volt A.C. ./ Above  180 Volt. A.C. For equipment Safety
6

光棍影院手机By Pass  Function (1)

By Pass  Function (2)

As per chart on  ELCB enclosure - metal body Semi Bypass = Bypass (1)
Fully Bypass = Bypass(2)
Facilities 7 Emergency indication Emergency Light Facility      For light up the area.
8 Emergency  Audible Signal Siren Facility It informs that there is a fault in system.
9 Fully Automatic - Self Start Within 5 second

Auto Reset

 

10 Fault  Indication LED Display On  front  panel display
11 Tripping Time  Less than 30mSec.   High speed  Responses
12 Highly sophisticated Control Circuit operated Relay mechanism High precision available For instant tripping & isolates the defective installation
13 TEST  Function Push the button  ‘ TEST ’ to check the healthy function of ELCB To confirm the Earth leakage test